Desktop software for sanitary engineering: wastewater and water
Sanitation design from sewer to discharge, in a single program
Build the plant flowsheet, simulate the treatment, check it against discharge standards, lay out and size the sewer and water networks over the terrain, and come away with calculation reports, drawing sheets and a technical report generated from the same project.
How it works
Five steps, one project
The flowsheet is the project's single source of truth. Sizing, simulation, verification and the report all read the same plant, and at every step the software tells you what is up to date and what is still missing.
- 1
Flowsheet
Drag in the elements, connect the streams, or start from a ready-made plant.
- 2
Size
Each block opens its own calculator, prefilled with the plant influent.
- 3
Simulate
Steady state or dynamic, with a monitor for any tank or stream.
- 4
Verify
Mass balance, convergence and compliance with the selected standards.
- 5
Report
Assessment, calculation report, tables and charts in PDF with the software seal.
Treatment plant
Treatment plant flowsheet and simulation
From screening to sludge dewatering, with reference biological models and blocks for the technologies used in Brazil.
Models the industry knows
- Activated sludge with the ASM1, ASM2d and ASM3 models, plus two-step ASM3 with anammox.
- Anaerobic digestion with ADM1, layered secondary clarifier (Takács) and N₂O emissions.
- Blocks for MBBR, IFAS, UASB, ponds in series, SBR, MBR, UV, chlorine, equalization, digester and dewatering.
- The BSM1 benchmark plant was checked in steady state against the published reference (maximum deviation of 0.31%).
Dynamic simulation
Run the plant over time with a variable influent (24-hour profile, rain, peak load) and follow any tank or stream on the monitor. The example shows the equalization tank: the incoming flow ranges from 11.6 to 32.4 L/s, while the flow sent to the reactor leaves at a constant 23.2 L/s.
There is also an automatic search for the plant's limits (how far it still meets the standard), user-defined scenarios and local satellite climate data (NASA POWER and JAXA) for month-by-month sewage temperature, always as optional, declared data.
Every number with its origin
Every parameter states where it came from: measured, entered, assumed or imported, with the source next to it. The suggest-values button fills only the empty fields and records the rule it used, and everything remains editable.
When the engine rejects a calculation, the screen explains the cause in plain language (the interface is in Portuguese), says what to do and offers a button to fix it.
Sizing
79 sanitary engineering calculators
Organized by stage (hydraulics, influent, treatment, post-treatment, sludge and operation), each with a bibliographic reference, validity range and calculation report.
Hydraulics and pumping
Pressure pipes (Darcy–Weisbach and Hazen–Williams), Manning, backwater, hydraulic jump, weirs, inverted siphon, plant hydraulic profile with 28 components, wet well, pumps in series or parallel with NPSH, variable frequency drive and emergency overflow.
Water supply
Distribution network per NBR 12218 with pressure zones and an EPANET file, pumped networks, transmission mains with water hammer, flocculator by velocity gradient (Camp and Stein) and chemical dosing.
Treatment
Screening, grit chamber, Parshall flume, grease trap, equalization, primary clarifier, activated sludge, biofilm, UASB, ponds, wetlands and septic tank with anaerobic filter (NBR 17076).
Post-treatment and discharge
Chlorine and UV disinfection, phosphorus precipitation, flocculation, receiving water self-purification (Streeter–Phelps) and compliance for reuse.
Sludge
Thickening, dewatering, drying beds, digestion (ADM1) and agronomic biosolids application rate based on nitrogen and metals.
Operation, odor and corrosion
Sulfide and H₂S in sewers and force mains with concrete corrosion, oxygen control loop, and quality and operating cost indicators.
2D flow
Flow inside the tank
Simulate baffled tanks, contact chambers and ponds in two dimensions, using shallow water or Navier–Stokes (laminar or k-ε). The software computes the residence time curve with t10, t50 and t90, the Morrill index, dead zones, particle settling on the bottom and mixing at the dosing point.
The calculated baffle factor can be passed on to the disinfection block of the flowsheet as a declared assumption.
Satellite data
Satellite data where it improves the design
The software fetches satellite and reanalysis data for the project area and uses it as declared, optional input, never as validation. Each dataset keeps its product, version, resolution, date and hash, is stored on your computer and is only requested with your permission, because the request reveals the coordinates.
Local climate
Air temperature, humidity, wind and radiation from NASA POWER since 1981 and rainfall from JAXA GSMaP since 1998, on 0.1° cells, by month, by season and with the extremes.
Critical month for the plant
The plant runs for all 12 months with the tank temperature from a heat balance, using satellite solar and longwave radiation, and the software points out the month that governs the design.
Terrain
ANADEM (bare-earth terrain derived from Copernicus, 30 m) or Copernicus GLO-30 where there is no survey, each with its published vertical error.
Buildings
Rooftops detected in satellite imagery by Google Open Buildings, with the detector confidence and a precision threshold you choose.
Network design
Sewer and water networks over the terrain
Draw the area on the map and the software gathers the terrain, the streets and the population. It then lays out the network following the slope, sizes it to the standard, checks it in SWMM and generates the drawing sheets. In the engineer's order: first the layout and the manholes, then the sizing.
- Area and terrainDTM from SIGSC (1 m, Santa Catarina), ANADEM or Copernicus, or your own topographic, drone or LiDAR survey or contour lines.
- City base dataStreets from OpenStreetMap, 2022 Census tracts and CNEFE addresses (IBGE, Brazil), buildings from Google Open Buildings.
- DemandPopulation per address, per capita, K1, K2 and K3 peaking factors, growth from the Censuses and design horizon.
- Sewer networkLayout by slope, manholes at intersections and changes of direction, sizing per Brazilian standards NBR 9649 and NBR 14486.
- Pumping stations and WWTPPumping stations where gravity is not enough, with force mains.
- ProfilesProfile of each sewer line with terrain, pipe crown, water depth, drop pipes and force main.
- Verification and drawingsDynamic wave in SWMM, DXF and PDF drawing sheets and export to QGIS, Civil 3D and BIM.
- Water networkDistribution per NBR 12218, pressures, pressure zones with PRVs and EPANET file.
Every design criterion comes from a standard or the literature, with the source alongside, and everything is editable. In the “your standards” area you register your utility's method and reuse it across all projects.
Project outputs
Drawings and files for your workflow
Plan and profiles in DXF, in project coordinates, and in PDF, in A0 to A3 sizes, at the standard NBR 8196 scale series and with a title block.
- DXF + PDFplan and profile sheets
- GeoPackagefor QGIS
- LandXMLfor Civil 3D
- IFC 4.3for BIM, georeferenced
- .inpfor EPANET
- CSVtables and streams
Technical report
Assessment and calculation report in PDF
One click generates the project's technical document: step status, flowsheet, design basis and sizing, every saved simulation with tables and charts, compliance with standards, process indicators, verification and a list of what is still missing. It comes out as PDF, with a header and footer on every page, and also as HTML.
The report is generated from a frozen project: what is on paper is exactly what was calculated.
Why trust the results
Rules the software follows in every calculation
No made-up numbers
A coefficient with no single value in the literature is your input, with its source. Without data, the field stays marked as having no data, never filled with a hidden value.
Failures come with the cause
Outside the validity range, without convergence or with an impossible result, the calculation stops and explains why, instead of delivering a plausible but wrong number.
A source for every criterion
Standard, book or paper, with clause or page. The calculation report shows where each value came from and which assumptions were used.
Calculation on your computer
The engine runs locally and calculations do not depend on the internet. Public data (terrain, streets, census, climate) is downloaded once and kept.
Installation
Software for Windows
- Windows 10 or 11, 64-bit.
- Its own installer, with the calculation engine included.
- Licensed per computer.
- Signed updates, offered by the software itself.
Who it is for
Sanitation designers and consultancies, water and sewer utilities and public agencies, and engineers who need to go from concept study to detailed design with a traceable calculation report.
Contact us
Want to see WPTreatment on your project?
Request a demo or licensing information.